This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Track device being used
Biosignalsplux Inductive Respiration (RIP) Sensor
- Manufacturer: PLUX
- Order number: EXP-R53-032
- Manufacturer part number: 820201240
- country of origin: PT
- HS code: 85423990
- Weight (kg): 0.1
Biosignalsplux Inductive sensor with adjustable chest strap... high performance even in dynamic... more
Biosignalsplux Inductive sensor with adjustable chest strap... high performance even in dynamic settings.
This high-performance inductive respiration sensor has been specifically designed to have dynamic conditions in mind (e.g. ambulatory sensing). The sensing element is embedded in the chest strap fabric and spans its full length.
The elastic chest-belt can be adjusted in length to be applicable on different anatomies (e.g. male and/or female), body locations (e.g. thorax and/or abdomen), and thorax/abdomen circumferences. Typical applications of this sensor include respiration monitoring to determine respiration cycles, rates, relative amplitudes, and other features.
NOTE: This sensor is only compatible with biosignalsplux acquisition system
This high-performance inductive respiration sensor has been specifically designed to have dynamic conditions in mind (e.g. ambulatory sensing). The sensing element is embedded in the chest strap fabric and spans its full length.
The elastic chest-belt can be adjusted in length to be applicable on different anatomies (e.g. male and/or female), body locations (e.g. thorax and/or abdomen), and thorax/abdomen circumferences. Typical applications of this sensor include respiration monitoring to determine respiration cycles, rates, relative amplitudes, and other features.
Features:
- Inductive measurement
- Adjustable elastic chest strap
- Displacement measurement
- Pre-conditioned analog output
- Raw signal output
- Ready-to-use & miniaturized form-factor
Specifications:
- Type: Inductive
- Output: 0-3V
- Consumption: ~1mA
- Cable Length: 100cm±0.5cm (customizable; extra costs may apply)
- Connector Type: UC-E6 (male; must be connected to a biosignalsplux acquisition unit)
- Max sensor belt length; 103cm
- Min sensor belt length: 44cm
NOTE: This sensor is only compatible with biosignalsplux acquisition system